• ±î¸£¶ì¿¡ ¸ÞÁ¾ Àç°ÇÃà
  • Renovation of Cartier Maison
  • - Project : ±î¸£¶ì¿¡ ¸ÞÁ¾ Àç°ÇÃà, 2014
    - Work Scope : Seismic Performance Evaluation, Investigation of the condition of the building
    - Analysis Program : Perform 3D (Pushover Analysis)
    - Location : Seoul, Korea
    - Occupancy : Neighborhood Facilities
    - Size : 2,643§³, B3F/6F (Height : 23.4m)
    - Structure System : Reinforced concrete
    - Client : CARTIER MAISON
  • Renovation of Cartier Maison
  • Renovation of Cartier Maison
  • Renovation of Cartier Maison

    Seismic performance evaluation is conducted on the building which has been designed based on prescriptive code.
    The Structural performance is verified by the static pushover analysis.
    Acceptance criteria to be used in demonstrating the capacity limit are the story drift and the element inelastic deformation on both service and MCE level.
    Structural member rotation and damper capacity at certain location and level are satisfied by the capacity limits.